Canada Oilfield Equipment

Loading gallery…

Offshore NOV 180K Nitrogen Skid Pumper Unit

Description

Offshore NOV 180K Nitrogen Skid Pumper Unit

Hydra Rig NOV 180K Offshore Nitrogen Pumper Unit:

  • Make: Hydra Rig / NOV
  • Equipment Type: Offshore Nitrogen Pumper
  • Nitrogen Rate: 180,000 SCFH
  • Cold Ends: 1-5/8”
  • Engine: Detroit Diesel Series 60
  • Engine Rating: 550 BHP
  • Engine Hours Since Rebuild: 0
  • Pump: CS&P Triplex Pump
  • Working Pressure: 15,000 PSI stated for heat pot/system
  • High-Pressure Iron: 1502, inspected and recertified
  • Skid Certification: DNV 2.7-1
  • Lifting Package: Certified DNV sling set and shackles
  • Fuel Type: Diesel
  • Condition: Refurbished
  • 2,000 gallon nitrogen tanks

Additional Information

  • Hydra Rig / NOV 180K SCF Nitrogen Pumper
  • Offshore skid-mounted nitrogen pumping unit
  • C1D2 Detroit Diesel Series 60 engine rated at 550 BHP
  • Engine fully disassembled and rebuilt
  • Engine has 0 hours since rebuild
  • New engine components include crank, bearings, pistons, liners, injectors, seal kit, and hoses
  • Remanufactured engine components include turbo, head, injector pump, and air compressor
  • Emergency air intake shut-off valve installed for emergency shutdown
  • Radiator boiled, cleaned, and tested
  • Hydraulic pump drive removed, torn down, inspected, and rebuilt with new bearing races and seals
  • New flex plate installed
  • Hydraulic pumps disassembled, inspected, reassembled, and tested to factory specifications
  • Hydraulic tank and system cleaned
  • Filters and required hydraulic components replaced as needed
  • All hoses replaced with new hoses sized and pressure-rated for system service
  • Air tank pressure tested and tagged as required
  • New safety relief valve installed
  • Rebuilt air starter installed
  • Rebuilt air compressor installed
  • Electrical system inspected and repaired as needed
  • Rebuilt alternator
  • New charging and ground wires
  • Gel battery
  • LED lights
  • Pressure gauges replaced as necessary
  • Pressure gauges and chart recorder recertified and rebuilt
  • Unit blasted, three-coat zinc primed, painted blue, and top-coated
  • CS&P triplex pump
  • 1-5/8” cold ends
  • Heat pot and system stated as rated for 15,000 PSI working pressure
  • Boost pump inspected and repaired as needed
  • Exhaust system inspected and repaired as needed
  • Exhaust wrapped with insulation from turbo to tail pipe
  • High-pressure stainless steel fittings, tubing, and valves inspected and repaired or replaced as needed
  • High-pressure 1502 iron inspected and recertified
  • Newly fabricated DNV 2.7-1 certified skid
  • Skid full-load tested with certified paperwork
  • Certified DNV sling set and shackles included
  • All components and systems to be tested at MULE Services facility prior to shipping
  • Liquid N2 testing to be completed with any leaks or repairs corrected prior to release
  • Unit complete and ready to be tested with customer
  • Tanks to be blasted, painted, and vacuum checked
  • Gauges to be recertified
  • PRVs to be replaced or certified

 

Offshore NOV 180K Nitrogen Skid Pumper Unit

Description

Offshore NOV 180K Nitrogen Skid Pumper Unit

Hydra Rig NOV 180K Offshore Nitrogen Pumper Unit:

  • Make: Hydra Rig / NOV
  • Equipment Type: Offshore Nitrogen Pumper
  • Nitrogen Rate: 180,000 SCFH
  • Cold Ends: 1-5/8”
  • Engine: Detroit Diesel Series 60
  • Engine Rating: 550 BHP
  • Engine Hours Since Rebuild: 0
  • Pump: CS&P Triplex Pump
  • Working Pressure: 15,000 PSI stated for heat pot/system
  • High-Pressure Iron: 1502, inspected and recertified
  • Skid Certification: DNV 2.7-1
  • Lifting Package: Certified DNV sling set and shackles
  • Fuel Type: Diesel
  • Condition: Refurbished
  • 2,000 gallon nitrogen tanks

Additional Information

  • Hydra Rig / NOV 180K SCF Nitrogen Pumper
  • Offshore skid-mounted nitrogen pumping unit
  • C1D2 Detroit Diesel Series 60 engine rated at 550 BHP
  • Engine fully disassembled and rebuilt
  • Engine has 0 hours since rebuild
  • New engine components include crank, bearings, pistons, liners, injectors, seal kit, and hoses
  • Remanufactured engine components include turbo, head, injector pump, and air compressor
  • Emergency air intake shut-off valve installed for emergency shutdown
  • Radiator boiled, cleaned, and tested
  • Hydraulic pump drive removed, torn down, inspected, and rebuilt with new bearing races and seals
  • New flex plate installed
  • Hydraulic pumps disassembled, inspected, reassembled, and tested to factory specifications
  • Hydraulic tank and system cleaned
  • Filters and required hydraulic components replaced as needed
  • All hoses replaced with new hoses sized and pressure-rated for system service
  • Air tank pressure tested and tagged as required
  • New safety relief valve installed
  • Rebuilt air starter installed
  • Rebuilt air compressor installed
  • Electrical system inspected and repaired as needed
  • Rebuilt alternator
  • New charging and ground wires
  • Gel battery
  • LED lights
  • Pressure gauges replaced as necessary
  • Pressure gauges and chart recorder recertified and rebuilt
  • Unit blasted, three-coat zinc primed, painted blue, and top-coated
  • CS&P triplex pump
  • 1-5/8” cold ends
  • Heat pot and system stated as rated for 15,000 PSI working pressure
  • Boost pump inspected and repaired as needed
  • Exhaust system inspected and repaired as needed
  • Exhaust wrapped with insulation from turbo to tail pipe
  • High-pressure stainless steel fittings, tubing, and valves inspected and repaired or replaced as needed
  • High-pressure 1502 iron inspected and recertified
  • Newly fabricated DNV 2.7-1 certified skid
  • Skid full-load tested with certified paperwork
  • Certified DNV sling set and shackles included
  • All components and systems to be tested at MULE Services facility prior to shipping
  • Liquid N2 testing to be completed with any leaks or repairs corrected prior to release
  • Unit complete and ready to be tested with customer
  • Tanks to be blasted, painted, and vacuum checked
  • Gauges to be recertified
  • PRVs to be replaced or certified